www.johnsonsystems.com 15
Quick Programming Reference to System Configuration Menu Items
1. SCENESET Enable and setup 24 different backup scenes.
2. FADETIME Set the fade time for each of the 24 scenes from 0 to 99 seconds.
3. SNAPSHOT Record DMX levels into the backup scenes.
4. DIM TEST Test the dimmer outputs one at a time, or all at once.
5. MONITOR View the control level to each dimmer output.
6. ADDRESS Set the DMX start address.
7. DMX MODE Congure the mode of the on-board DMX protocol manager.
8. 2 RM SET Set the two room assignment for each of the dimmer outputs.
9. DMXA TRM Enable or disable termination on the DMX A input.
10. DMXB TRM Enable or disable termination on the DMX B input.
11. DMX O/P Congure the on-board DMX protocol manager for offset or patch mode.
12. DMXA PAT Patch the 24 dimmer (PWM) outputs to any DMX A input channel.
13. DMXB PAT Patch the 24 dimmer (PWM) outputs to any DMX B input channel.
14. SH TIME Set the DMX status hold time from 0 to 99 minutes or innite.
15. DC PATCH Congure the dimmer to channel patch for the dimmer rack.
16. DIM CURV Congure the dimmer curve for each output.
17. VOUT LIM Set the maximum RMS output voltage for each dimmer.
18. REGULATE Enable or disable the dimmer output voltage regulation.
19. ANA MODE Congure the analog inputs for normal or load shed mode.
20. ANA PTCH Patch the analog inputs to any combination of control channels.
21. ANA TEST View the control level for each of the analog inputs.
22. ANA FLTR Apply a noise lter on the analog inputs of up to 1 Volt.
23. ANA BLOC Enable or disable the analog inputs when DMX is being received.
24. STANDBY Enable or disable the power savings standby mode.
25. TEST INC Set the test increment units to percent or hexadecimal.
26. OC MODE Congure the input trigger parameters for the open collector output.
27. AUX IN Select which scene the auxiliary input will trigger/enable.
28. L-BUTTON Set the mode of the local buttons to scene, bump or disabled.
29. S-ALARM Select the level and control channels triggered by the security alarm input.
30. F-ALARM Select the level and control channels triggered by the re alarm input.
31. Ø-PATCH Set the zero-cross phase reference for each dimmer control output circuit.
32. WARMING Turn the “lamp warming” feature on or off.
33. POLARITY Set the PWM output control polarity. Locked for factory use only!
34. LINE V View the RMS line voltage for each power phase.
35. LINE F View the line frequency of phase A.
36. REM TEMP View the temperature of the remote temperature sensor.
37. CTL TEMP View the temperature of the microcontroller.
38. RTIME View the total run time of the microcontroller.
39. HARD-KEY View the microcontroller’s unique six-character hard-key code.
40. SERIAL# View the microcontroller’s unique six-character silicone serial number.
41. VERSION View the microcontroller’s rmware version.
42. EEPROM View the type of EEPROM memory module plugged in.
43. FW-LOAD Load new rmware into the MADD-24 via the EEPROM memory module.
44. RESTORE Restore parameters saved in the EEPROM memory module.
45. BACKUP Backup parameters and save them in the EEPROM memory module.
46. PRINTOUT Print various system conguration settings using a hand held infrared printer.
47. DEFAULTS Set various system conguration settings to the factory default.
48. LCD VIEW Adjust the contrast of the LCD Display for optimum viewing.
Komentáře k této Příručce